SUBJECT: Amateur Radio Shack Designs, part 2
GROUNDING: The ground system to your shack is as important as the
electrical system. But, keep in mind that are two ground systems
here. First, there is the electrical ground which concerns your power
system and second, there is the RF ground. In most Ham Shacks these
two grounding systems are separate and sometimes by a considerable
distance in relation to your shack/home.
The grounding hole in the electrical socket (see figure 1) is NOT
an RF grounding point!
Figure 1: o <-------- Ground
| |
^ ^
| |__________ Neutral (Large slot)
|
|____________ Hot (Small slot)
This arrangement may be inverted in you home/shack. I prefer to
see where the ground plugs in first being a rather tall individual.
Neutral is basically at ground potential and a meter reading with a
VOM will show little or no votage potential difference between ground
and neutral. Ground to hot or neutral to hot will exhibit 115VAC
(pluss or minus the normal variations from you local power and light
company). The reason you DO NOT want to use the electrical ground
for your radio shack is that there is potential for this ground to
carry an electrical potential! Also, this ground can be up to 100
feet from the socket in a house and up to 600 feet or more in an
apartment complex! Holy longwire, Batman! And that ground is
connected to many other people's dwellings! Holy Bitch and Gripe
from the neighbors, Batman!
****************************************
I have gone to many a ham's homes on RFI problems only to find
their favorite grounding point is the commercial ground. I remove it
and have them run a separate ground. The RFI goes away. Please keep
this in mind.
****************************************
Your RF ground should also be a central point, BUT NOT THE
COMMERCIAL GROUND! Single point grounding is the best bet to keep
RFI under control, provides a point where there is no DC potential,
and provides the shortest point to ground for the transceivers and
antennas. When you consider your shack design, locate the ground
such that the run is as short as possible. In apartments, a cold
water pipe beats no ground at all and beats the commercial ground
by a mile. Be sure to check that the commercial ground is not the
cold water pipe also (This I've seen many times, $$ savings during
construction).
Grounding Layout: Again, I'll use my shack as the example.
|
| Tower
| X
--------------------------------------------------------- |
| -----------|----|
| Ground wire |
| |
| |
| |
| |
| |
| |
| |
|---------------------------|
|
The ground Wire is a #6 Copper wire connected to a 10 foot ground
rod into the water table (Florida water table is 4 ft). The tower is
also connected to the same ground point. The ground rod is located
next to the tower as close as possible outside the cement base. The
base is a 1946 design ground distribution system and is electrical
connected to the ground rod. All equipment from VHF to HF linears are
connected to the system at on point in the shack and one point in the
ground. DC potential is zero.
-WS